You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

105 lines
3.3 KiB

/******************************************************************************
*
* Copyright 2014 Broadcom Corporation
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*
******************************************************************************/
#include <string.h>
#include "bt_target.h"
#include "bt_types.h"
#include "btm_ble_api.h"
#include "btm_int.h"
#include "btu.h"
#include "hcidefs.h"
#include "hcimsgs.h"
#include "stack/btm/btm_int_types.h"
#include "utils/include/bt_utils.h"
extern tBTM_CB btm_cb;
tBTM_BLE_ENERGY_INFO_CB ble_energy_info_cb;
/*******************************************************************************
*
* Function btm_ble_cont_energy_cmpl_cback
*
* Description Controller VSC complete callback
*
* Parameters
*
* Returns void
*
******************************************************************************/
static void btm_ble_cont_energy_cmpl_cback(tBTM_VSC_CMPL* p_params) {
uint8_t* p = p_params->p_param_buf;
uint16_t len = p_params->param_len;
uint32_t total_tx_time = 0, total_rx_time = 0, total_idle_time = 0,
total_energy_used = 0;
if (len < 17) {
BTM_TRACE_ERROR("wrong length for btm_ble_cont_energy_cmpl_cback");
return;
}
uint8_t raw_status;
STREAM_TO_UINT8(raw_status, p);
tHCI_STATUS status = to_hci_status_code(raw_status);
STREAM_TO_UINT32(total_tx_time, p);
STREAM_TO_UINT32(total_rx_time, p);
STREAM_TO_UINT32(total_idle_time, p);
STREAM_TO_UINT32(total_energy_used, p);
BTM_TRACE_DEBUG(
"energy_info status=%d,tx_t=%ld, rx_t=%ld, ener_used=%ld, idle_t=%ld",
status, total_tx_time, total_rx_time, total_energy_used, total_idle_time);
if (NULL != ble_energy_info_cb.p_ener_cback)
ble_energy_info_cb.p_ener_cback(total_tx_time, total_rx_time,
total_idle_time, total_energy_used,
static_cast<tHCI_STATUS>(status));
return;
}
/*******************************************************************************
*
* Function BTM_BleGetEnergyInfo
*
* Description This function obtains the energy info
*
* Parameters p_ener_cback - Callback pointer
*
* Returns status
*
******************************************************************************/
tBTM_STATUS BTM_BleGetEnergyInfo(tBTM_BLE_ENERGY_INFO_CBACK* p_ener_cback) {
tBTM_BLE_VSC_CB cmn_ble_vsc_cb;
BTM_BleGetVendorCapabilities(&cmn_ble_vsc_cb);
BTM_TRACE_EVENT("BTM_BleGetEnergyInfo");
if (0 == cmn_ble_vsc_cb.energy_support) {
BTM_TRACE_ERROR("Controller does not support get energy info");
return BTM_ERR_PROCESSING;
}
ble_energy_info_cb.p_ener_cback = p_ener_cback;
BTM_VendorSpecificCommand(HCI_BLE_ENERGY_INFO, 0, NULL,
btm_ble_cont_energy_cmpl_cback);
return BTM_CMD_STARTED;
}