You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
jianglk.darker 7ee447c011
v811_spc009_project
7 months ago
..
Kconfig v811_spc009_project 7 months ago
Makefile v811_spc009_project 7 months ago
README v811_spc009_project 7 months ago
TODO v811_spc009_project 7 months ago
bcma_private.h v811_spc009_project 7 months ago
core.c v811_spc009_project 7 months ago
driver_chipcommon.c v811_spc009_project 7 months ago
driver_chipcommon_b.c v811_spc009_project 7 months ago
driver_chipcommon_nflash.c v811_spc009_project 7 months ago
driver_chipcommon_pflash.c v811_spc009_project 7 months ago
driver_chipcommon_pmu.c v811_spc009_project 7 months ago
driver_chipcommon_sflash.c v811_spc009_project 7 months ago
driver_gmac_cmn.c v811_spc009_project 7 months ago
driver_gpio.c v811_spc009_project 7 months ago
driver_mips.c v811_spc009_project 7 months ago
driver_pci.c v811_spc009_project 7 months ago
driver_pci_host.c v811_spc009_project 7 months ago
driver_pcie2.c v811_spc009_project 7 months ago
host_pci.c v811_spc009_project 7 months ago
host_soc.c v811_spc009_project 7 months ago
main.c v811_spc009_project 7 months ago
scan.c v811_spc009_project 7 months ago
scan.h v811_spc009_project 7 months ago
sprom.c v811_spc009_project 7 months ago

README

Broadcom introduced new bus as replacement for older SSB. It is based on AMBA,
however from programming point of view there is nothing AMBA specific we use.

Standard AMBA drivers are platform specific, have hardcoded addresses and use
AMBA standard fields like CID and PID.

In case of Broadcom's cards every device consists of:
1) Broadcom specific AMBA device. It is put on AMBA bus, but can not be treated
   as standard AMBA device. Reading it's CID or PID can cause machine lockup.
2) AMBA standard devices called ports or wrappers. They have CIDs (AMBA_CID)
   and PIDs (0x103BB369), but we do not use that info for anything. One of that
   devices is used for managing Broadcom specific core.

Addresses of AMBA devices are not hardcoded in driver and have to be read from
EPROM.

In this situation we decided to introduce separated bus. It can contain up to
16 devices identified by Broadcom specific fields: manufacturer, id, revision
and class.