# Copyright 2019 The Chromium OS Authors. All rights reserved.
|
|
# Use of this source code is governed by a BSD-style license that can be
|
|
# found in the LICENSE file.
|
|
|
|
from autotest_lib.client.common_lib import utils
|
|
from autotest_lib.server.hosts import cros_host
|
|
|
|
AUTHOR = 'ncrews'
|
|
DEPENDENCIES = "servo_state:WORKING"
|
|
NAME = 'policy_DeviceChargingServer.BatteryChargeMode'
|
|
TIME = 'LONG'
|
|
TEST_CATEGORY = 'General'
|
|
TEST_CLASS = 'enterprise'
|
|
TEST_TYPE = 'server'
|
|
ATTRIBUTES = "suite:wilco_bve"
|
|
|
|
DOC = """
|
|
Ensures the DUT's battery level is in a testable range, clears the TPM if
|
|
needed, and then runs the specified client test to verify charging behavior
|
|
is consistent with policies.
|
|
"""
|
|
|
|
args_dict = utils.args_to_dict(args)
|
|
servo_args = cros_host.CrosHost.get_servo_arguments(args_dict)
|
|
|
|
client_test = 'policy_DeviceCharging'
|
|
|
|
# When DeviceBatteryChargeMode is set to BATTERY_CHARGE_PRIMARILY_AC_USE, then
|
|
# the DUT will not charge when above 86%. In order to test this, we need to be
|
|
# above this threshold.
|
|
MIN_BATTERY_LEVEL = 87
|
|
|
|
# A test case consists of the policies, plus the expected power behavior.
|
|
TEST_CASES = [
|
|
({'DeviceBatteryChargeMode': 1}, # BATTERY_CHARGE_STANDARD
|
|
'ON_AC_AND_CHARGING'),
|
|
({'DeviceBatteryChargeMode': 2}, # BATTERY_CHARGE_EXPRESS_CHARGE
|
|
'ON_AC_AND_CHARGING'),
|
|
({'DeviceBatteryChargeMode': 3}, # BATTERY_CHARGE_PRIMARILY_AC_USE
|
|
'ON_AC_AND_CHARGING'),
|
|
({'DeviceBatteryChargeMode': 4}, # `BATTERY_CHARGE_ADAPTIVE
|
|
'ON_AC_AND_CHARGING'),
|
|
({'DeviceBatteryChargeMode': 5, # BATTERY_CHARGE_CUSTOM
|
|
'DeviceBatteryChargeCustomStartCharging': 50,
|
|
'DeviceBatteryChargeCustomStopCharging': 60},
|
|
'ON_AC_AND_NOT_CHARGING'),
|
|
({'DeviceBatteryChargeMode': 5, # BATTERY_CHARGE_CUSTOM
|
|
'DeviceBatteryChargeCustomStartCharging': 50,
|
|
'DeviceBatteryChargeCustomStopCharging': 100},
|
|
'ON_AC_AND_CHARGING'),
|
|
]
|
|
|
|
# These are used to cleanup the DUT and to prep the DUT before each test case.
|
|
# See the test for more info.
|
|
ON_AC_AND_CHARGING_POLICIES = {
|
|
'DeviceBatteryChargeMode': 1, # BATTERY_CHARGE_STANDARD
|
|
}
|
|
ON_AC_AND_NOT_CHARGING_POLICIES = {
|
|
'DeviceBatteryChargeMode': 5, # BATTERY_CHARGE_CUSTOM
|
|
'DeviceBatteryChargeCustomStartCharging': 50,
|
|
'DeviceBatteryChargeCustomStopCharging': 60,
|
|
}
|
|
PREP_POLICIES = {
|
|
'ON_AC_AND_CHARGING' : (ON_AC_AND_NOT_CHARGING_POLICIES,
|
|
'ON_AC_AND_NOT_CHARGING'),
|
|
'ON_AC_AND_NOT_CHARGING' : (ON_AC_AND_CHARGING_POLICIES,
|
|
'ON_AC_AND_CHARGING'),
|
|
}
|
|
|
|
def run(machine):
|
|
host = hosts.create_host(machine, servo_args=servo_args)
|
|
job.run_test('policy_DeviceChargingServer',
|
|
host=host,
|
|
client_test=client_test,
|
|
test_cases=TEST_CASES,
|
|
min_battery_level=MIN_BATTERY_LEVEL,
|
|
prep_policies=PREP_POLICIES)
|
|
|
|
parallel_simple(run, machines)
|